If a transformer has 50 turns in the primary winding and 10 turns on the secondary winding, what is the reflected resistance in the primary if the secondary load resistance is 250 W?

Respuesta :

Answer:

The reflected resistance in the primary winding is 6250 Ω

Explanation:

Given;

number of turns in the primary winding, [tex]N_P[/tex] = 50 turns

number of turns in the secondary winding, [tex]N_S[/tex] = 10 turns

the secondary load resistance, [tex]R_S[/tex] = 250 Ω

Determine the turns ratio;

[tex]K = \frac{N_P}{N_S} \\\\K = \frac{50}{10} \\\\K = 5[/tex]

Now, determine the reflected resistance in the primary winding;

[tex]\frac{R_P}{R_S} = K^2\\\\R_P = R_SK^2\\\\R_P = 250(5)^2\\\\R_P = 6250 \ Ohms[/tex]

Therefore, the reflected resistance in the primary winding is 6250 Ω