Answer:
To* = 1074.9k ( stagnation temperature )
Po* = 0.467 MPa ( stagnation pressure )
Explanation:
Given data:
Po1 = 1.6 MPa
To = 430°c + 273 = 703 k
Mach number at inlet ( M1 )= 3
Mach number at exit ( M2 ) = 1
at M1 = 3
To1 / To* = 0.65398 ( value gotten from Rayleigh's flow gas tables )
therefore To* = 1074.9k
also
Po1 / Po* = 3.42445 ( value gotten from Rayleigh's flow gas tables )
therefore Po* = 0.467 MPa
at M2 = 1
To2 = To* = 1074.9k
Po2 = Po* = 0.467 MPa
using both Rayleigh's flow table and Isentropic Tables the values of stagnation temperature and stagnation pressure are the same at the exit